TDS
Defines the released grade, indicative properties, applications and handling guidance. It is not a batch result.
Evidence library
Documents are grouped by issuing party and purpose so buyers can distinguish company certifications, product testing and supplier batch inspection records.
| Document / grade | Available here | Scope / next step |
|---|---|---|
| Company management systems | ISO certificate records | Company-system scope; not product or application approval. |
| Standard-type PCE test | 2024 report scans | Historical tested sample; request current grade evidence separately. |
| EPEG-3000 · E240422-4 | Supplier batch PDF | Report dated 22 April 2024; named upstream batch only. |
| HPEG-2400H · H240418-6 | Supplier batch PDF | Report dated 19 April 2024; named upstream batch only. |
| TPEG-2400 · T240506-2 | Supplier batch PDF | Report dated 7 May 2024; does not certify TPEG-3000. |
| Current grade TDS / SDS | Request documents | Identify the exact grade, destination and required revision. |
| Shipment COA | Request batch confirmation | Match the actual order and lot; a historical example is not shipment evidence. |
For a new supplier or grade, compare identity and document scope before comparing numbers. The monomer COA checklist explains the questions to ask.
ISO management-system certificates identify Huahai Feifei (Hebei) Concrete Admixture Co., Ltd.. They certify the stated management-system scope; they are not product certifications.
Current product-document workflow
Product documents are released by product, grade and available version. A company certificate, a historical test report and an upstream supplier batch report do not replace the current product TDS, SDS or order-specific COA.
Confirm the selected grade, revision and applicable technical limits.
Request the current safety document before handling, storage or transport planning.
Confirm batch-specific acceptance values with the commercial order.
Use only evidence that identifies the sample, method, date and issuing party.
Independent test report
Hebei Academy of Building Research Co., Ltd. issued report 冀建检(化)2024-03129 for a standard-type polycarboxylate high-performance water-reducing admixture submitted by Huahai Feifei.
| Water-reduction rate | 29% (requirement ≥25%) |
|---|---|
| 1-hour slump loss | 20 mm (requirement ≤80 mm) |
| Air content | 4.1% (requirement ≤6.0%) |
| Compressive-strength ratio | 1d 180%; 3d 164%; 7d 159%; 28d 148% |
| 28-day shrinkage ratio | 93% (requirement ≤110%) |
Results apply to the tested sample and test conditions; they are not a guarantee for every current grade or concrete mix.
Review the report pages →
Patent record
The supplied three-page registration record covers invention patent ZL201710260451.2 and records the transfer of the patent right to Huahai Feifei (Hebei) Concrete Admixture Co., Ltd. on 26 May 2022.
The scans are presented as ownership/registration evidence. Product performance claims must still be supported by the applicable current specification and test data.
These PDFs were issued by Lianyungang Petrochemical Co., Ltd. for individual EPEG, HPEG and TPEG batches. They are supplier batch inspection records—not Huahai Feifei certificates and not independent third-party product certifications.
Confirms a management system and stated organizational scope.
Reports results for the submitted sample under stated test conditions.
Records inspection results for a specific upstream raw-material batch.
Buyer document checklist
A certificate or report is useful only when its identity, scope, date and issuing party match the product and transaction being reviewed.
Defines the released grade, indicative properties, applications and handling guidance. It is not a batch result.
Communicates hazards, handling, transport and emergency information for a named product and supplier.
Links a batch number to specification limits and actual test results. It does not replace application testing.
Records materials, method, dosage basis and measured results for a defined test—not a universal guarantee.
For an SSD-based aggregate quantity, use the aggregate moisture correction calculator with measured moisture and absorption for each fraction. Keep test method, sample time and source with the result.
Use the slump retention calculator to summarize time-stamped readings, or the concrete admixture troubleshooter to organize a control-based checking sequence. These tools do not replace product documents, project test methods or acceptance criteria.
HFC-1001 Liquid PCE Superplasticizer — grade-specific properties, application boundaries and document review status.
Original product data sheet (Chinese PDF). Supplied original, unchanged; naming/revision details require confirmation. This file is not a batch COA or independent certification.
Keep the evidence and assumptions with a named grade enquiry. These buyer guides complement the technical material above.